Paper Title :Investigation on Axial Capacity of Circular Concrete Columns Confined with Ferrocement Pre-Jacketing
Author :Akm. Rubayat Mahmud Bhuiyan, Anik Das, Noshin Saiyara, Md. Mashfiqul Islam
Article Citation :Akm. Rubayat Mahmud Bhuiyan ,Anik Das ,Noshin Saiyara ,Md. Mashfiqul Islam ,
(2017 ) " Investigation on Axial Capacity of Circular Concrete Columns Confined with Ferrocement Pre-Jacketing " ,
International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) ,
pp. 55-59,
Volume-4,Issue-6
Abstract : This paper presents an experimental study on axial capacity of circular concrete columns confined with
Ferrocement pre-jacketing. In this research woven mesh is used as a pre-jacketing material to improve the behavior of
structural circular column under axial compression load. The confinement effect over the circular column is uniform
compared to the same of a non-circular column. In this study total 6 specimens are tested where crushed stone and clay
burnt brick chips used as a coarse aggregate. For comparing the increased capacity of stress and strain with jacketed
specimens, 2 specimens are non-jacketed as control specimen. Confined specimens showed higher strength than the
unconfined specimens under compressive load. Besides, the stress–strain behavior indicates that double layer of
Ferrocement jacket provides significant confining stress than single layer mesh.
Keywords - Woven wire mesh, ferrocement, pre-jacketing, wrap number, stress-strain curve.
Type : Research paper
Published : Volume-4,Issue-6
DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-10668
View Here
Copyright: © Institute of Research and Journals
|
|
| |
|
PDF |
| |
Viewed - 47 |
| |
Published on 2018-03-23 |
|