International Journal of Advances in Mechanical and Civil Engineering (IJAMCE)
.
Follow Us On :
current issues
Volume-11,Issue-1  ( Feb, 2024 )
Past issues
  1. Volume-11,Issue-1  ( Feb, 2024 )
  2. Volume-10,Issue-6  ( Dec, 2023 )
  3. Volume-10,Issue-5  ( Oct, 2023 )
  4. Volume-10,Issue-4  ( Aug, 2023 )
  5. Volume-10,Issue-3  ( Jun, 2023 )
  6. Volume-10,Issue-2  ( Apr, 2023 )
  7. Volume-10,Issue-1  ( Feb, 2023 )
  8. Volume-9,Issue-6  ( Dec, 2022 )
  9. Volume-9,Issue-5  ( Oct, 2022 )
  10. Volume-9,Issue-4  ( Aug, 2022 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 58
Paper Published : 1075
No. of Authors : 2871
  Journal Paper


Paper Title :
Punching Shear Behavior of RC Flat Plate with Openings Rested on Coupled Columns

Author :Alaa Elsayed, Mahmoud Elsayed, Doaa M. Saad

Article Citation :Alaa Elsayed ,Mahmoud Elsayed ,Doaa M. Saad , (2018 ) " Punching Shear Behavior of RC Flat Plate with Openings Rested on Coupled Columns " , International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) , pp. 99-105, Volume-5,Issue-3

Abstract : Supporting a reinforced concrete slabs by coupled columns may cause them to behave as one column or as two separate columns according to the distance in between. In this research, the punching shear behavior of RC flat slabs with openings supported by square interior coupled columns were investigated. A total of twelve two-way RC slabs with interior two columns were constructed and tested. All the test specimens were quadratic with 1000 mm length and 65 mm thick., and have a centrally coupled square column stubs of 100 mm sides and 150 mm height. Three variables were considered in this research which is, the separation distance of the columns (d, 2d, 3d, and 4d), the location of the opening, and the distance from column face to the opening. The test results indicated that the punching shear capacity increased gradually by increasing the clear distance between columns. The experimental results showed a decrease in punching shear capacity in specimens with opening ranged between 10 % and 32% in comparison to the control specimen without opening. Index Terms - Coupled columns, Flat plate slab, Punching Shear, Opening.

Type : Research paper

Published : Volume-5,Issue-3


DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-13074   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 53
| Published on 2018-09-05
   
   
IRAJ Other Journals
IJAMCE updates
IJAMCE Vol-11, Iss-1 (Feb 2024)
The Conference World

JOURNAL SUPPORTED BY