International Journal of Advances in Mechanical and Civil Engineering (IJAMCE)
.
Follow Us On :
current issues
Volume-11,Issue-1  ( Feb, 2024 )
Past issues
  1. Volume-11,Issue-1  ( Feb, 2024 )
  2. Volume-10,Issue-6  ( Dec, 2023 )
  3. Volume-10,Issue-5  ( Oct, 2023 )
  4. Volume-10,Issue-4  ( Aug, 2023 )
  5. Volume-10,Issue-3  ( Jun, 2023 )
  6. Volume-10,Issue-2  ( Apr, 2023 )
  7. Volume-10,Issue-1  ( Feb, 2023 )
  8. Volume-9,Issue-6  ( Dec, 2022 )
  9. Volume-9,Issue-5  ( Oct, 2022 )
  10. Volume-9,Issue-4  ( Aug, 2022 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 58
Paper Published : 1075
No. of Authors : 2871
  Journal Paper


Paper Title :
The Investigation of Basalt and Glass Fibers on The Behavior of Reinforced Concrete Beams

Author :Duaa Fadil, Nildem Taysi, Abdullah Ahmed

Article Citation :Duaa Fadil ,Nildem Taysi ,Abdullah Ahmed , (2018 ) " The Investigation of Basalt and Glass Fibers on The Behavior of Reinforced Concrete Beams " , International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) , pp. 16-19, Volume-5,Issue-3

Abstract : This paper presents an experimental study aimed at determining the compressive, tensile and flexural behavior of concrete members containing different percentages of Basalt Fiber (BF) and Glass Fiber (GF). The diameter of BF and GF are 12-30 μm and 13μm respectively, both BF and GF are hooked ends deformed with 12 mm length. The mixtures contain the combination of BF and GF fibers. Control beam is without fiber, BF0.5 is (0.5 % BF), BF1 is (1 % BF), BF1.5 is (1.5 % BF), BF0.25GF0.75 is (0.25 % BF and 0.75 % GF), GF0.25BF0.75 is (0.25 % GF and 0.75 % BF) and BF0.5GF0.5 is (0.5 % BF and 0.5 % GF). The total volume of fibers is constant at 1 % for the hybrid fiber reinforced concrete beams. All mixtures are designed for high strength concrete (30 MPa). From the test results, it is observed that there is no significant effect of fiber inclusion on the compressive strength of concrete moreover BF concrete usually has higher tensile strength than GF. According to standards 28 days after casting fiber reinforced concrete beams are tested by two point loading. The flexural strength of beams are increasing with the increase of BF content in a gradual fashion but no such change was observed for GF reinforced concrete. Index terms- Basalt fiber (BF), Glass fiber (GF), compressive strength, tensile strength, flexural strength.

Type : Research paper

Published : Volume-5,Issue-3


DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-13057   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 52
| Published on 2018-09-05
   
   
IRAJ Other Journals
IJAMCE updates
IJAMCE Vol-11, Iss-1 (Feb 2024)
The Conference World

JOURNAL SUPPORTED BY