Paper Title :Punching Shear Behavior of RC Flat Plate with Openings Rested on Coupled Columns
Author :Alaa Elsayed, Mahmoud Elsayed, Doaa M. Saad
Article Citation :Alaa Elsayed ,Mahmoud Elsayed ,Doaa M. Saad ,
(2018 ) " Punching Shear Behavior of RC Flat Plate with Openings Rested on Coupled Columns " ,
International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) ,
pp. 99-105,
Volume-5,Issue-3
Abstract : Supporting a reinforced concrete slabs by coupled columns may cause them to behave as one column or as two
separate columns according to the distance in between. In this research, the punching shear behavior of RC flat slabs with
openings supported by square interior coupled columns were investigated. A total of twelve two-way RC slabs with interior
two columns were constructed and tested. All the test specimens were quadratic with 1000 mm length and 65 mm thick., and
have a centrally coupled square column stubs of 100 mm sides and 150 mm height. Three variables were considered in this
research which is, the separation distance of the columns (d, 2d, 3d, and 4d), the location of the opening, and the distance from
column face to the opening. The test results indicated that the punching shear capacity increased gradually by increasing the
clear distance between columns. The experimental results showed a decrease in punching shear capacity in specimens with
opening ranged between 10 % and 32% in comparison to the control specimen without opening.
Index Terms - Coupled columns, Flat plate slab, Punching Shear, Opening.
Type : Research paper
Published : Volume-5,Issue-3
DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-13074
View Here
Copyright: © Institute of Research and Journals
|
|
| |
|
PDF |
| |
Viewed - 53 |
| |
Published on 2018-09-05 |
|