Paper Title :Vulnerability of Retrofitting Technique for an Irregular Structure
Author :Monika Nihichlani, Meena Murmu
Article Citation :Monika Nihichlani ,Meena Murmu ,
(2018 ) " Vulnerability of Retrofitting Technique for an Irregular Structure " ,
International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) ,
pp. 106-110,
Volume-5,Issue-3
Abstract : An existing 3-storey, 2- Bay reinforced concrete structure with plan irregularity, both in as-built before and as
retrofitted is subjected only to gravity load in the framework of performance of existing structure and its rehabilitation
research project. The structure is analyzed by a linear-dynamic statistical method to get the response of structure for
computing time period, storey shear and maximum storey displacement in each mode of vibration. In this episode the
structure retrofitted by column- jacketing, a strengthening technique to increase the system capacity and ductility. The design
of retrofitting technique is incorporated by using extended three dimensional analysis of building system (ETABS 2015).
Keywords - Response Spectrum Method, ETABS , Retrofitting, Column Jacketing, Irregular.
Type : Research paper
Published : Volume-5,Issue-3
DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-13075
View Here
Copyright: © Institute of Research and Journals
|
|
| |
|
PDF |
| |
Viewed - 50 |
| |
Published on 2018-09-05 |
|